Home >
Stramit Building Products >
Residential Walling
RESIDENTIAL WALLING
Appraisals, Tests :
Monopanel® 250 |
|
|
Monopanel® 250
|
Pressures
Seviceability Limit State Capacity
| span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
2100 |
2400 |
2700 |
| internal |
4.57 |
3.06 |
2.30 |
1.84 |
1.54 |
1.32 |
1.15 |
1.02 |
| equal |
4.57 |
3.06 |
2.30 |
1.84 |
1.54 |
1.32 |
1.15 |
1.02 |
| double |
5.19 |
3.47 |
2.61 |
2.09 |
1.74 |
1.49 |
1.31 |
1.16 |
Strength State Capacity (Non-cyclonic)
| span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
2100 |
2400 |
2700 |
| internal |
7.29 |
4.46 |
3.19 |
2.48 |
2.03 |
1.72 |
1.49 |
1.31 |
| equal |
7.29 |
4.46 |
3.19 |
2.48 |
2.03 |
1.72 |
1.49 |
1.31 |
| double |
8.17 |
5.00 |
3.58 |
2.78 |
2.28 |
1.92 |
1.67 |
1.47 |
Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3.
Internal spans must have both ends spans 20% shorter. Values only valid for use with steel support members of 0.75mm or thicker. |
|
|