Pressures
Seviceability Limit State Capacity
| span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
| internal |
3.41 |
2.39 |
1.84 |
1.49 |
1.25 |
| equal |
3.41 |
2.39 |
1.84 |
1.49 |
1.25 |
| double |
3.41 |
2.39 |
1.84 |
1.49 |
1.25 |
Strength State Capacity (Non-cyclonic)
| span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
| internal |
5.79 |
2.67 |
1.56 |
1.04 |
0.74 |
| equal |
5.79 |
2.67 |
1.56 |
1.04 |
0.74 |
| double |
5.79 |
2.67 |
1.56 |
1.04 |
0.74 |
Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3.
Internal spans must have both ends spans 20% shorter. Values only valid for use with steel support members of 0.75mm or thicker.
Data shown is for 0.42mm Stramit Minirib® Panelling |
|
|