Home >
Stramit Building Products >
Residential Walling
RESIDENTIAL WALLING
Appraisals, Tests :
K-Panel® |
|
|
K-Panel®
|
Pressures
Seviceability Limit State Capacity
thickness
BMT |
fasteners
/sheet |
span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
| 0.35 |
4 |
internal |
4.23 |
1.87 |
1.03 |
0.64 |
0.42 |
| equal |
2.94 |
1.29 |
0.70 |
0.42 |
0.26 |
| double |
2.55 |
1.12 |
0.61 |
0.36 |
0.23 |
| 0.42 |
4 |
internal |
5.60 |
2.48 |
1.37 |
0.84 |
0.55 |
| equal |
3.89 |
1.70 |
0.92 |
0.55 |
0.35 |
| double |
3.38 |
1.48 |
0.80 |
0.48 |
0.30 |
Strength State Capacity (Non-cyclonic)
thickness
BMT |
fasteners
/sheet |
span type |
pressure (kPa) at the spans (mm) shown |
| 600 |
900 |
1200 |
1500 |
1800 |
| 0.35 |
4 |
internal |
12.5 |
7.75 |
5.28 |
3.77 |
2.75 |
| equal |
10.1 |
6.11 |
4.02 |
2.75 |
1.89 |
| double |
9.87 |
5.93 |
3.90 |
2.67 |
1.84 |
| 0.42 |
4 |
internal |
15.3 |
9.48 |
6.45 |
4.61 |
3.36 |
| equal |
12.4 |
7.47 |
4.91 |
3.36 |
2.32 |
| double |
12.1 |
7.24 |
4.77 |
3.26 |
2.25 |
Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3.
Internal spans must have both ends spans 20% shorter. Values only valid for use with steel support members of 0.75mm or thicker.
|
|
|
All products contained herein © Stramit Building Products. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|