Selector.com
Selector.com - Part of Architecture Media Product Network Australian Institute of Architects
Selector.com
Home | About Us | Contact Us | Links | Sitemap Advertise your products
  or    or  Guest
Existing user?  Login
New to site?  Register
 
COMPANY INFORMATION
PRODUCT INFORMATION
Residential Walling
 Photographs
 Colours & Textures
 Technical DataClick to view subproduct listing
 Specify ProductClick to view subproduct listing
 ApplicationsClick to view subproduct listing
 Install, MaintainClick to view subproduct listing
 FeaturesClick to view subproduct listing
 Appraisals, Tests
Corrugated
K-Panel®
Minirib®
Monopanel® 250
Other products by this company
Roof & Ceiling Battens
Formwork
Purlins & Girts
Rainwater Products
more products...
EDITORIAL
Architects Handbook
Stramit Building Products
Stramit Speed Deck Ultra® Decking
Stramit Condeck Hp® Composite Decking
Stramit® Optimized Purlin System
Stramit Speed Deck Ultra® Decking
Stramit® Optimized Purlin System
Stramit Condeck Hp® Composite Decking
Architectural Product News
STRAMIT STEEL CREATES A STYLISH SOLUTION
STRAMIT UNIGUARD: QUICK, FIRE-RESISTING WALLS
STRAMIT® PREMIUM CLADDING
Similar products by all companies
Metal wall cladding
 

Home > Stramit Building Products > Residential Walling

  RESIDENTIAL WALLING
  Appraisals, Tests : Corrugated

Corrugated
Adverse Conditions
Stramit® Corrugated cladding will give excellent durability in almost all locations. It is however important to choose the correct coating for each application environment. The table below shows the suitability of coating types for different exposure conditions
suitability of
coating type
site exposure condition
benign moderate severe very severe
Zincalume AZ150 ? ?
Galvanised Z450 ?
Colorbond XRW ?
Colorbond XSE N/A N/A ?
? Question marks indicate conditions where durability may be diminished, depending on the particular application.

The approximate site exposure conditions in the table above are defined below.

distance of site from
site exposure condition rough active surf calm, still salt water industrial emmision fossil fuel combustion
benign 1000m + 100m + 500m + 500m +
moderate 400m-1000m 0-100m 250m-500m 250m-500m
severe 100m-400m N/A 100m-250m 100m-250m
very severe 0-100m N/A 0-100m 0-100m


Spans
The spans shown below take account of 'normal' foot traffic and wind resistance including local pressure zone effects. Pressures are based on AS4055 or AS1170.2 section 2. Where the two standards differ, the worst case has been taken for each classification.
Data should only be used for buildings 7m or less in height, 1000m2 or less in area and unaffected by land topography.

Maximum Span Chart (mm)
Fasteners
per sheet
at each support
Roofs Overhangs
bmt (mm) pressure (kPa) internal (end) span combination free edge stiffened edge
serviceability strength double span equal spans
N1 and N2 or Region B (sheltered suburban) and Region A (sheltered suburban and exposed suburban)
0.42 3 screws
5 screws
0.78
0.78
1.94
1.94
900
900
900
900
1200 (1000)
1200 (1000)
100
100
250
250
0.48 3 screws
5 screws
0.78
0.78
1.94
1.94
1200
1200
1200
1200
1600 (1300)
1600 (1300)
100
100
300
300
0.60 3 screws
5 screws
0.78
0.78
1.94
1.94
900
900
900
900
1200 (1000)
1200 (1000)
100
100
250
250
N3 or Region A (rural) and Region B (exposed suburban)
0.42 3 screws
5 screws
1.18
1.18
2.96
2.96
900
900
900
900
1200 (1000)
1200 (1000)
100
100
200
200
0.48 3 screws
5 screws
1.18
1.18
2.96
2.96
1200
1200
1200
1200
1600 (1300)
1600 (1300)
100
100
250
250
0.60 3 screws
5 screws
1.18
1.18
2.96
2.96
900
900
900
900
1200 (1000)
1200 (1000)
100
100
200
200
Walls
N1 and N2 or Region B (sheltered suburban) and Region A (sheltered suburban and exposed suburban)
0.42 3 screws
5 screws
0.61
0.61
1.49
1.49
2050
2100
2050
2100
2650 (2200)
2500 (2050)
0.48 3 screws
5 screws
0.61
0.61
1.49
1.49
2300
2300
2300
2300
2850 (2350)
2750 (2250)
0.60 3 screws
5 screws
0.61
0.61
1.49
1.49
2550
2500
2550
2500
3000 (2500)
3000 (2500)
N3 or Region A (rural) and Region B (exposed suburban)
0.42 3 screws
5 screws
0.92
0.92
2.25
2.25
1600
1750
1600
1750
2150 (1750)
2150 (1750)
0.48 3 screws
5 screws
0.92
0.92
2.25
2.25
1750
2000
1750
2000
2250 (1850)
2350 (1950)
0.60 3 screws
5 screws
0.92
0.92
2.25
2.25
2200
2100
2200
2100
2600 (2150)
2500 (2050)
Internal spans must have both end spans 20% shorter. Values are only valid for use with steel members of 0.75mm or thicker. For more specific applications Stramit® Corrugated cladding must be designed to the pressure and foot traffic limitations below.


Pressures

Serviceability Limit State Capacity
thickness
bmt (mm)
fasteners
per sheet
span type (kPa) at the spans (mm) shown
600 900 1200 1500 1800 2100 2400 2700 3000
0.42 3 internal
equal
double
2.14
2.15
2.15
1.93
1.68
1.68
1.44
1.39
1.39
1.27
1.05
1.05
1.10
0.74
0.74
0.98
0.60
0.60
0.76
0.44
0.44
0.59
0.31
0.31
0.45
0.20
0.20
5 internal
equal
double
8.19
6.97
6.97
6.13
4.55
4.55
3.17
2.54
2.54
2.20
1.50
1.50
1.50
0.89
0.89
1.00
0.61
0.61
0.69
0.42
0.42
0.50
0.30
0.30
0.37
0.24
0.24
0.48 3 internal
equal
double
4.12
4.12
4.12
2.87
2.07
2.07
1.95
1.39
1.39
1.52
1.15
1.15
1.23
0.91
0.91
1.01
0.72
0.72
0.83
0.56
0.56
0.68
0.39
0.39
0.55
0.31
0.31
5 internal
equal
double
8.19
6.97
6.97
6.30
5.49
5.49
4.41
2.99
2.99
2.73
1.82
1.82
1.82
1.18
1.18
1.26
0.79
0.79
0.90
0.54
0.54
0.65
0.36
0.36
0.47
0.23
0.23
0.60 3 internal
equal
double
4.71
4.45
4.45
3.88
3.33
3.33
3.01
2.36
2.36
2.34
1.83
1.83
1.83
1.27
1.27
1.43
1.01
1.01
1.12
0.74
0.74
0.87
0.52
0.52
0.66
0.34
0.34
5 internal
equal
double
9.54
9.54
9.54
6.39
4.61
4.61
3.81
2.74
2.74
2.54
1.81
1.81
1.81
1.27
1.27
1.34
0.92
0.92
1.02
0.68
0.68
0.79
0.51
0.51
0.62
0.38
0.38


Strength Limit State Capacity (Non-Cyclonic)
thickness
bmt (mm)
fasteners
per sheet
span type (kPa) at the spans (mm) shown
600 900 1200 1500 1800 2100 2400 2700 3000
0.42 3 internal
equal
double
10.33
10.33
10.33
9.45
6.83
6.83
6.08
4.52
4.52
5.15
3.91
3.91
4.22
3.30
3.30
3.82
3.18
3.18
3.43
2.53
2.53
2.84
2.01
2.01
2.35
1.58
1.58
5 internal
equal
double
12.43
11.41
11.41
12.43
10.50
10.50
10.20
7.25
7.25
9.29
6.82
6.82
7.81
6.39
6.39
6.60
5.26
5.26
5.60
4.35
4.35
4.78
3.60
3.60
4.08
2.98
2.98
0.48 3 internal
equal
double
12.43
11.41
11.41
10.03
9.34
9.34
7.92
7.14
7.14
6.37
5.62
5.62
4.50
4.37
4.37
4.08
3.69
3.69
3.66
3.04
3.04
3.11
2.53
2.53
2.66
2.10
2.10
5 internal
equal
double
12.43
11.41
11.41
12.43
10.31
10.31
11.87
9.30
9.30
9.56
8.29
8.29
7.84
7.64
7.64
6.53
6.25
6.25
5.50
5.00
5.00
4.67
3.94
3.94
3.99
3.04
3.04
0.60 3 internal
equal
double
12.43
10.20
12.00
9.93
8.88
10.40
9.53
8.14
9.58
8.71
6.90
8.19
7.58
5.70
6.70
6.46
4.51
5.30
5.35
3.44
4.05
4.33
2.50
2.94
3.41
1.67
1.96
5 internal
equal
double
12.43
11.49
11.49
12.43
11.49
11.49
12.43
11.49
11.49
12.43
10.44
11.49
11.42
8.54
10.05
9.69
6.76
7.95
8.03
5.16
6.07
6.50
3.75
4.41
5.11
2.50
2.95
Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3. Internal spans must have bothe end spans 20% shorter.
Values only valid for use with steel support members of 0.75mm or thicker.


Foot Traffic
Foot traffic limits for Stramit® Corrugated cladding are shown for three alternate foot traffic categories. These are:
  • High Maintenance - for applications with repeated maintenance, particularly where personnel may be unfamiliar with correct procedures for walking on metal roofs.
  • Normal - based on traditional expectations, with moderate maintenance foot traffic using designated foot paths.
  • Controlled - spans that conform to AS 1562 but require minimal careful foot traffic only on the designated foot path. Suggested for use only where occasional aesthetic imperfections from foot traffic are acceptable.
bmt (mm) span type high maintenance normal controlled
0.42 internal - 1200 1500
equal - 900 900
double - 900 900
0.48 internal 750 1600 1800
equal 500 1200 1500
double 500 1200 1500
0.60 internal - 1200 1900
equal - 900 1600
double - 900 1600
Tables are based on tests to AS1562 and AS4040 parts 0 and 1.

All products contained herein © Stramit Building Products. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd.
All rights reserved.