RESIDENTIAL ROOFING
Technical Data :
Speed Deck Ultra®
Speed Deck Ultra®
Materials
Stramit Speed Deck Ultra® decking is manufactured from hi-tensile G550 colour coated steel or zinc-aluminium alloy coated steel. In some locations galvanised and severe environmental colour coated steel may be available by arrangement. Colour coated steels are in accordance with AS2728 - Category 3 and, for the substrate, with AS1397. Zinc-aluminium alloy coated AZ150 and galvanised Z450 conform to AS1397
Sheet Mass (kg/m2 of roof area)
thickness BMT
Zincalume
Colorbond
Galvanised
0.42mm
4.66
4.74
5.07
0.48mm
5.29
5.37
5.70
Recommended Span Chart (mm)
Roofs
Overhangs
bmt (mm)
pressure (kPa)
internal (end) span combination
free edge
stiffened edge
serviceability
strength
double span
equal spans
N1 or Region A (sheltered suburban)
0.42
0.76
1.35
1700
1700
2100 (1750)
150
450
0.48
0.76
1.35
2300
2300
2700 (2250)
200
500
N2 or Region B (sheltered suburban) and Region A (exposed suburban)
0.42
0.78
1.94
1700
1700
2100 (1750)
150
450
0.48
0.78
1.94
2300
2300
2700 (2250)
200
500
N3 or Region A (rural) and Region B (exposed suburban)
0.42
1.18
2.96
1700
1700
2100 (1750)
150
450
0.48
1.18
2.96
2050
2250
2550 (2150)
200
500
Walls
N1 or Region A (sheltered suburban)
0.42
0.61
1.04
3000
2850
3000 (2500)
0.48
0.61
1.04
3000
2900
3000 (2500)
N2 or Region B (sheltered suburban) and Region A (exposed suburban)
0.42
0.61
1.49
3000
2850
3000 (2500)
0.48
0.61
1.49
3000
2900
3000 (2500)
N3 or Region A (rural) and Region B (exposed suburban)
0.42
0.92
2.25
2600
2350
2900 (2450)
0.48
0.92
2.25
2650
2450
2950 (2500)
Internal spans must have both end spans 20% shorter. Values are only valid for use with steel members of 1.5mm or thicker.
For more specific applications Stramit Speed Deck Ultra® decking must be designed to the pressure and foot traffic limitations below.
Spans may exceed those shown in this table, provided the wind pressure and foot traffic limits are not exceeded.
Spring Curving
Stramit Speed Deck Ultra® decking can be spring curved, concave and convex, including curved ridges, provided it is within the recommended limits below:
Spring-Curved Radii limits (m)
restricted minimum*
unrestricted
minimum
unrestricted
maximum
0.42bmt
0.48bmt
90*
70*
100
225
* At these radii a maximum support spacing of 1200mm applies, and limit state pressure capacities are reduced by 14% for serviceability and 7% for strength.
Water Carrying
Stramit Speed Deck UItra decking has excellent water-carrying capacity. This and the decking stiffness enable roof slopes to be as low as one degree for many applications. Roof run lengths are the combined lengths of all roof elements contributing to a single pan drainage path. This can include the roof length upstream of a roof penetration that concentrates flow into other pans. The table below gives slopes for 100 year return period rainfall intensity.
Minimum Roof Slope (degrees)
rainfall intensity
Total Roof Run Length (m)
50
60
70
80
90
100
110
120
130
140
150
150
1.0
1.1
1.4
175
minimum slope 1°
1.0
1.1
1.4
1.8
2.2
200
1.0
1.3
1.7
2.2
2.6
3.1
225
1.0
1.4
1.9
2.4
2.9
3.6
4.2
250
1.0
1.4
1.9
2.6
3.2
3.9
4.7
5.5
275
1.0
1.4
1.9
2.6
3.2
4.0
4.8
5.8
6.8
300
1.0
1.1
1.7
2.4
3.1
4.0
4.8
5.9
6.9
8.2
325
1.0
1.4
2.1
2.9
3.1
4.8
5.8
6.9
8.2
9.7
350
1.0
1.1
1.7
2.6
3.5
4.5
5.5
6.8
8.2
9.8
12
375
1.0
1.5
2.3
3.2
4.3
5.5
6.8
8.1
10
12
14
400
1.4
2.0
2.7
3.9
5.1
6.3
7.7
9.7
12
14
17
Maximum water protection is also ensured by the absence of fastener penetrations when using Stramit Speed Ultra® decking.