Selector.com
Selector.com - Part of Architecture Media Product Network Australian Institute of Architects
Selector.com
Home | About Us | Contact Us | Links | Sitemap Advertise your products
  or    or  Guest
Existing user?  Login
New to site?  Register
 
COMPANY INFORMATION
PRODUCT INFORMATION
Commercial Roofing
 Photographs
 Colours & Textures
 Technical DataClick to view subproduct listing
 Specify ProductClick to view subproduct listing
 ApplicationsClick to view subproduct listing
 Install, MaintainClick to view subproduct listing
 FeaturesClick to view subproduct listing
 Appraisals, Tests
Longspan®
Monoclad®
Speed Deck Ultra®
Other products by this company
Roof & Ceiling Battens
Formwork
Purlins & Girts
Rainwater Products
more products...
EDITORIAL
Architects Handbook
Stramit Building Products
Stramit Speed Deck Ultra® Decking
Stramit Condeck Hp® Composite Decking
Stramit® Optimized Purlin System
Stramit Speed Deck Ultra® Decking
Stramit® Optimized Purlin System
Stramit Condeck Hp® Composite Decking
Architectural Product News
STRAMIT STEEL CREATES A STYLISH SOLUTION
Similar products by all companies
Metal roofing
 

Home > Stramit Building Products > Commercial Roofing

  COMMERCIAL ROOFING
  Appraisals, Tests : Speed Deck Ultra®

Speed Deck Ultra®
Pressures

Serviceability Limit State Capacity
Bmt (mm) fasteners per sheet per purlin span type pressure (kPa) at the spans (mm) shown
600 900 1200 1500 1800 2100 2400 2700 3000
0.42 1 clip and 3 screws internal 2.81 2.81 2.53 2.24 1.96 1.68 1.39 1.11 0.83
equal 2.86 2.86 2.47 2.08 1.68 1.29 0.90 0.51
double 2.33 2.33 2.08 1.84 1.60 1.36 1.12 0.87 0.63
0.48 1 clip and 3 screws internal 3.12 3.12 2.80 2.49 2.18 1.86 1.55 1.23 0.92
equal 3.17 3.17 2.74 2.30 1.87 1.44 1.00 0.57
double 2.58 2.58 2.31 2.04 1.78 1.51 1.24 0.97 0.70


Strength Limit State Capacity (Cyclonic & Non-Cyclonic)
Bmt (mm) fasteners per sheet per purlin span type pressure (kPa) at the spans (mm) shown
600 900 1200 1500 1800 2100 2400 2700 3000
0.42 1 clip and 3 screws internal 7.91 7.91 6.16 5.07 4.32 3.78 3.36 3.03 2.77
equal 7.86 7.86 5.82 4.62 3.82 3.25 2.83 2.50 2.24
double 8.00 8.00 5.71 4.40 3.55 2.97 2.54 2.21 1.95
0.48 1 clip and 3 screws internal 8.55 8.55 6.65 5.47 4.67 4.08 3.63 3.27 2.99
equal 8.49 8.49 6.29 4.98 4.12 3.51 3.05 2.70 2.42
double 8.64 8.64 6.17 4.75 3.84 3.20 2.74 2.39 2.11
Tables are baased on testing to AS1562 and AS4040 parts 0, 2, and 3. Internal spans must have both end spans 20% shorter.

Values only valid for use with steel support members of 1.5mm or thicker.

Foot Traffic

Foot traffic limits for Stramit Speed Deck Ultra® decking are shown for three alternate foot traffic categories.
These are:
  • High maintenance - for applications with repeated maintenance, particularly where personnel may be unfamiliar with correct procedures for walking on metal roofs.
  • Normal - based on traditional expectations, with moderate maintenance foot traffic using designed foot paths.
  • Controlled - spans that conform to AS1562 but require minimal careful foot traffic only on the designated foot path. Suggested for use only where occasional aesthetic imperfections from foot traffic are acceptable.
bmt (mm) span type high maintenance normal controlled
0.42 internal 1100 2100 2700
equal 700 1700 2250
double 700 1700 2250
0.48 internal 1400 2700 3600
equal 900 2300 2700
double 900 2300 2700
Tables are based on tests to AS1562 and AS4040 parts 0 and 1.


Designing for Snow

Concealed fixed decking such as Stramit Speed Deck Ultra® decking is the preferred roofing material in alpine areas. This, and many other design suggestions, can be found in Australian Standards HB 106 - 'Guidelines for Design of Structures in Snow Areas'. Particular attention is drawn to maintaining an adequate roof slope for snow shedding, and screw fixing of deck pans beneath the ridge capping.

Downward load capacities for Stramit Speed Deck UItra® decking have not been tabulated, but can be assumed to equal the outward capacities shown.

Thermal Expansion

All metal roof sheeting is subject to thermal expansion and, where there is a temperature difference between the sheeting and the structure, this needs to be accommodated. The colour of the sheeting will affect the amount of thermal expansion, and whether the sheet is flat or curved will affect its ability to resist without problems.

Stramit Speed Deck Ultra® decking has excellent resistance to the problems associated with thermal expansion. Nevertheless sheet lengths should be limited to those shown below.

Maximum Sheet Length (m)
roof colour light dark
flat 35 25
Spring-curved 30 20

All products contained herein © Stramit Building Products. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd.