Home >
James Hardie Building Products >
Scyon™ Axon™ Cladding
SCYON™ AXON™ CLADDING
Appraisals, Tests :
Index |
|
Resistance to Fire
Scyon Axon cladding is suitable where non-combustable materials are required in accordance with C1.12 of the Building Code of Australia.Scyon Axon cladding by James Hardie has been tested by CSIRO and is classified as a group
1 material in accordance with Specification C1.10a of the BCA. Scyon sheets have the following early fire hazard indices (tested to AS 1530 Part 3).
| EARLY FIRE HAZARD INDICES |
| Ignition index |
0 |
| Flame spread index |
0 |
| Heat evolved index |
0 |
| Smoke developed index |
0-1 |
Note: Zero is the best possible result.
|