Home >
Boral Plasterboard >
Fire Resistant Wall Systems
FIRE RESISTANT WALL SYSTEMS
Technical Data :
PartiWALL® |
|
|
PartiWALL®
|
|
Fire-Rating
|
Acoustic Rating |
90mm Cavity
(70mm Studs) |
110mm Cavity (70mm or 90mm) |
| BCA Acoustic Requirement: Rw=45dB or Rw=50dB and impact sound resistance |
| System 25TP1010 |
/25TP1010.GIF) |
1 Hour
FRL 60/60/60
CSIRO Test
FSV - 0381
Opinions
FCO-2016
FCO-2256
|
Rw = 51dB
Acoustic Opinion
GH&A Sheet
No 89 - Rev B |
Rw = 55dB Acoustic Opinion
GH&A Sheet
No 89 - Rev B
(Based on RMIT 121I/00-22/KC) |
| System 50TP1010 |
/50TP1010.GIF) |
1.5 Hours
FRL 90/90/90
CSIRO Test
FSV - 0381
Opinions
FCO-2016
FCO-2256
|
Rw = 54dB
Acoustic Opinion
GH&A Sheet
No 89 - Rev B |
Rw = 59dB Acoustic Opinion
GH&A Sheet
No 89 - Rev B
|
| BCA Acoustic Requirement: Rw + Ctr=50dB and discontinouos construction (as required) |
| System 25TP2020 |
/25TP2020.GIF) |
1 Hour
FRL 90/90/90
CSIRO Test
FSV - 0381
Opinions
FCO-2016
FCO-2256
|
Rw + Ctr=50dB
Acoustic Opinion
GH&A Sheet
No 89 - Rev B |
Rw + Ctr=50dB
CSIRO Test TL429r
(with R1.5 batts both sides) |
| System 25TP1313A |
/25TP1313A.GIF) |
1 Hour
FRL 90/90/90
CSIRO Test
FSV - 0381
Opinions
FCO-2016
FCO-2256
|
NA |
Rw + Ctr=50dB
CSIRO Test TL429e |
| System 50TP1313A |
/50TP1313A.GIF) |
1.5 Hours
FRL 90/90/90
CSIRO Test
FSV - 0381
Opinions
FCO-2016
FCO-2256
|
Rw + Ctr=50dB
Acoustic Opinion
GH&A Sheet
No 89 - Rev B |
Rw + Ctr=53dB
Acoustic Opinion
GH&A Sheet
No 89 - Rev B |
NOTES:
- 10mm Boral Wet Area Plasterboard can be substituted for 10mm Boral Standard Core Plasterboard.
- 13mm Boral Wet Area FireSTOP Plasterboard can be substituted for 13mm Boral SoundSTOP® Plasterboard
- 90mm thick polyester batts with a min density 20kg/m³ can be substituted for glasswool batts.
|
Request a PDF
PartiWALL
|
|
|
All products contained herein © Boral Plasterboard. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|