FIRE RESISTANT WALL SYSTEMS
Features :
PartiWALL® |
|
|
PartiWALL®
|
- Satisfies Building Code of Australia acoustic provisions for separating walls in Class 1 buildings of Rw = 45dB, Rw = 50dB and Rw + Ctr = 50dB
- Achieves Building Code of Australia requirements of Rw = 30dB and Rw + Ctr = 25dB or R = 45dB and Rw + Ctr = 40dB acoustic separation of adjoining soil and waste pipes within the cavity.
- As the primary fire barrier (the ShaftLINER™ membrane) is located in the cavity between the frames, the system permits easy inclusion of services such as water and waste pipes, electrical and communications cables.
- System provides Fire Resistance Levels (FRL) of 60/60/60 and 90/90/90 with the structural adequacy and load bearing capacity being provided by the wall frame of the unit on the other side of the PartiWALL® membrane to a fire affected unit.
- Modular construction of ShaftLINER membrane permits easy installation at framing stage - no additional trades are required.
- Internal faces lined and finished as per normal finishing sequence.
- Cost effective and fast to construct.
- Outperforms masonry party walls for speed and flexibility of construction.
- No wet trades are required.
|
|
|