Home >
BlueScope Lysaght >
Residential Wall Cladding
RESIDENTIAL WALL CLADDING
Technical Data :
Lysaght Trimwall® |
|
|
Lysaght Trimwall®
|
Schematic
/2366011A001.GIF)
Physical Properties
| Mass and Yield |
BMT
(mm) |
kg/m |
kg/m2 |
m2/t |
| ZINCALUME® steel |
0.35 |
2.74 |
3.60 |
278 |
Tolerance
Cover: 762mm +/-4mm
Length Tolerance: +0, -10mm
Spanning Tables
The wall spacings indicated are the maximum recommended for buildings up to 10 m high in Region B Terrain Category 3 conditions (Vs = 38 m/s and Vu = 60 m/s), using Cpe = 0.65, Cpi = 0.2 and Kl = 2.0.
These spacings may be reduced by the servicability and strength wind conditions for the particular project under consideration.
Maximum Recommended Support Spacings (mm)
| Type of Span |
Thickness (mm) |
| Walls |
0.35 |
Single Span
End Span
Internal Span
Overhang |
2100
2900
3000
150 |
Capacity & Load Tables
The wind pressure capacities are based on tests conducted at BlueScope's NATA registered testing laboratory.
Testing was conducted in accordance with AS 1562.1 - 1992, Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 - 1992, Resistance to Wind Pressure for Non-cyclone Regions'
Serviceability Limit State is based on a deflection limit of: (span/120) + (P/30), where P is the maximum fastener pitch.
Strength Limit State capacities have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable when the cladding is fixed to a minimum of 1.0 mm material (G550).
To obtain the design capacity of sheeting, a capacity reduction factor should be applied (ø = 0.9).
| LYSAGHT TRIMWALL® - Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness
(mm) |
Type of
Span |
Limit
State |
Span (mm) |
| 600 |
900 |
1200 |
1500 |
1800 |
| 0.35 |
Single |
Serviceability |
2.81 |
2.28 |
1.80 |
1.39 |
1.05 |
| Strength |
7.40 |
5.15 |
3.40 |
2.55 |
2.05 |
| End |
Serviceability |
2.78 |
2.77 |
2.76 |
2.47 |
1.93 |
| Strength |
6.60 |
5.95 |
5.30 |
4.45 |
3.50 |
| Internal |
Serviceability |
2.83 |
2.73 |
2.57 |
2.30 |
1.96 |
| Strength |
7.50 |
7.00 |
6.40 |
5.45 |
4.35 |
| LYSAGHT TRIMWALL® - Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness
(mm) |
Type of
Span |
Limit
State |
Span (mm) |
| 2400 |
2100 |
2700 |
3000 |
3300 |
| 0.35 |
Single |
Serviceability |
0.75 |
0.48 |
- |
- |
- |
| Strength |
1.70 |
1.50 |
- |
- |
- |
| End |
Serviceability |
1.31 |
0.80 |
0.51 |
0.40 |
0.39 |
| Strength |
2.70 |
2.10 |
1.75 |
1.65 |
1.60 |
| Internal |
Serviceability |
1.58 |
1.23 |
0.92 |
0.65 |
0.40 |
| Strength |
3.30 |
2.50 |
2.00 |
1.80 |
1.75 |
NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads.
For further information please download the Lysaght's Trimwall Product Brochure. It is available in a PDF format from below.
Trimwall Product Brochure (207kb)
|
|
|
All products contained herein © BlueScope Lysaght. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|