Home >
BlueScope Lysaght >
Residential Wall Cladding
RESIDENTIAL WALL CLADDING
Technical Data :
Lysaght Panelrib® |
|
|
Lysaght Panelrib®
|
Schematic
/2366012A001.GIF)
Tolerance
Length Tolerance: +0, -15mm
Width Tolerance: +0, -4mm
Spanning Tables
The support spacings indicated are the maximum recommended for buildings up to 10m high in Region B Terrain Category 3 conditions (Vs = 38 m/s and Vu = 60 m/s) using Cpe = 0.65, Cpi = 0.2 and Kl = 2.0.
These spacings may be reduced by the Serviceablitiy and Strength wind conditions for the particular project under consideration.
Maximum Recommended Support Spacings (mm)
| Type of Span |
Thickness |
| Walls |
0.35 |
0.42 |
Single Span
End Span
Internal Span
Overhang |
1100
1200
1200
150 |
1200
1200
1200
150 |
Maximum support spacing for internal ceiling applications is 1200mm for end and internal spans.
Capacity & Load Tables
The wind pressure capacities are based on tests conducted at BlueScope's NATA registered testing laboratory.
Testing was conducted in accordance with AS 1562.1 1992, Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 1992, Resistance to Wind Pressure for Non-cyclonic Regions.
Serviceability Limit State is based on deflection limit of: (span/120) + (P/30), where P is the maximum fastener pitch.
Strength Limit State capacities have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable when cladding is fixed to a minimum of 1.0 mm material.
Strength pressure is reduced when fixed to material <1.0 mm. To obtain the design capacity of sheeting, a capacity reduction factor should be applied (ø=0.9).
| LYSAGHT PANELRIB® Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness
(mm) |
Type of
Span |
Fasteners
per sheet
per support |
Limit
State |
Span (mm) |
| 600 |
700 |
800 |
900 |
1000 |
| 0.35 |
Single |
4 |
Serviceability |
2.11 |
1.74 |
1.39 |
1.06 |
0.76 |
| Strength |
10.50 |
9.50 |
8.55 |
7.60 |
6.75 |
| 8 |
Serviceability |
2.01 |
1.67 |
1.34 |
1.03 |
0.75 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
12.00 |
| End |
4 |
Serviceability |
3.39 |
2.80 |
2.22 |
1.68 |
1.19 |
| Strength |
8.20 |
7.35 |
6.50 |
5.75 |
5.00 |
| 8 |
Serviceability |
2.78 |
2.29 |
1.82 |
1.38 |
0.98 |
| Strength |
12.00 |
11.35 |
10.30 |
9.25 |
8.30 |
| Internal |
4 |
Serviceability |
3.95 |
3.32 |
2.71 |
2.13 |
1.61 |
| Strength |
9.20 |
8.30 |
7.45 |
6.65 |
5.90 |
| 8 |
Serviceability |
3.63 |
3.02 |
2.44 |
1.88 |
1.38 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
10.95 |
| 0.42 |
Single |
4 |
Serviceability |
2.18 |
1.82 |
1.48 |
1.15 |
0.86 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
11.10 |
| 8 |
Serviceability |
1.92 |
1.63 |
1.34 |
1.07 |
0.82 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
12.00 |
| End |
4 |
Serviceability |
3.60 |
3.00 |
2.42 |
1.87 |
1.38 |
| Strength |
9.20 |
8.35 |
7.50 |
6.75 |
6.00 |
| 8 |
Serviceability |
2.90 |
2.37 |
1.86 |
1.38 |
0.95 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
12.00 |
| Internal |
4 |
Serviceability |
6.21 |
5.09 |
4.01 |
3.00 |
2.09 |
| Strength |
11.50 |
10.40 |
9.35 |
8.35 |
7.45 |
| 8 |
Serviceability |
4.60 |
3.79 |
3.00 |
2.27 |
1.61 |
| Strength |
12.00 |
12.00 |
12.00 |
12.00 |
12.00 |
| LYSAGHT PANELRIB® Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness
(mm) |
Type of
Span |
Fasteners
per sheet
per support |
Limit
State |
Span (mm) |
| 1100 |
1200 |
1300 |
2366 |
1500 |
| 0.35 |
Single |
4 |
Serviceability |
0.51 |
0.31 |
0.18 |
- |
- |
| Strength |
6.00 |
5.40 |
4.90 |
- |
- |
| 8 |
Serviceability |
0.52 |
0.33 |
0.20 |
- |
- |
| Strength |
10.80 |
9.80 |
9.00 |
- |
- |
| End |
4 |
Serviceability |
0.78 |
0.45 |
0.23 |
- |
- |
| Strength |
4.35 |
3.80 |
3.35 |
- |
- |
| 8 |
Serviceability |
0.64 |
0.37 |
0.19 |
- |
- |
| Strength |
7.40 |
6.70 |
6.10 |
- |
- |
| Internal |
4 |
Serviceability |
1.15 |
0.78 |
0.51 |
0.32 |
0.19 |
| Strength |
5.25 |
4.70 |
4.25 |
3.95 |
3.75 |
| 8 |
Serviceability |
0.95 |
0.60 |
0.35 |
0.19 |
0.10 |
| Strength |
9.85 |
8.90 |
8.10 |
7.55 |
7.05 |
| 0.42 |
Single |
4 |
Serviceability |
0.61 |
0.41 |
0.27 |
0.18 |
0.13 |
| Strength |
10.00 |
9.00 |
8.15 |
7.45 |
6.85 |
| 8 |
Serviceability |
0.61 |
0.44 |
0.32 |
0.23 |
0.17 |
| Strength |
12.00 |
12.00 |
11.25 |
10.70 |
10.35 |
| End |
4 |
Serviceability |
0.95 |
0.61 |
0.37 |
0.21 |
0.12 |
| Strength |
5.35 |
4.80 |
4.30 |
3.95 |
3.65 |
| 8 |
Serviceability |
0.59 |
0.31 |
0.12 |
- |
- |
| Strength |
10.80 |
9.70 |
8.80 |
- |
- |
| Internal |
4 |
Serviceability |
1.32 |
0.73 |
0.33 |
0.10 |
- |
| Strength |
6.65 |
6.00 |
5.50 |
5.10 |
4.85 |
| 8 |
Serviceability |
1.05 |
0.61 |
0.32 |
0.14 |
0.07 |
| Strength |
12.00 |
11.50 |
10.60 |
9.90 |
9.35 |
NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads
For further information please download Lysaght's Panel Rib Product Brochure. It is available from below in a PDF format.
Panel Rib Product Brochure (213kb)
|
|
|
All products contained herein © BlueScope Lysaght. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|