Selector.com
Selector.com - Part of Architecture Media Product Network Australian Institute of Architects
Selector.com
Home | About Us | Contact Us | Links | Sitemap Advertise your products
  or    or  Guest
Existing user?  Login
New to site?  Register
 
COMPANY INFORMATION
PRODUCT INFORMATION
Residential Roof Cladding
 Photographs
 Colours & TexturesClick to view subproduct listing
 Technical Data
Lysaght Custom Orb®
Lysaght Custom Blue Orb®
Lysaght Trimdek®
Lysaght Spandek®
Lysaght Klip-Lok® 406
Lysaght klip-Lok® 700
 Specify ProductClick to view subproduct listing
 ApplicationsClick to view subproduct listing
 Install, MaintainClick to view subproduct listing
 FeaturesClick to view subproduct listing
 Appraisals, TestsClick to view subproduct listing
Other products by this company
Residential Carports & Verandahs
Residential Flooring
Fencing
Steel Beams
more products...
EDITORIAL
Architects Handbook
The Lysaght Roofing Range – Quality And Style
Lysaght Structural Products
Lysaght Mini Orb®
Lysaght W-dek®
Lysaght Mini Orb®
Lysaght Quikafloor® – Steel For Strength
The Lysaght® Roofing Range
Architectural Product News
A FRESH APPROACH TO FACADE SOLUTIONS
THERE’S SOMETHING UNIQUE BEHIND THE BEST FACADES ...
Similar products by all companies
Metal roofing
 

Home > BlueScope Lysaght > Residential Roof Cladding

  RESIDENTIAL ROOF CLADDING
  Technical Data : Lysaght klip-Lok® 700

Lysaght klip-Lok® 700
Schematic



Physical Properties

Mass and Yield
Thickness
(mm BMT)
ZINCALUME steel
kg/m kg/m2 m2/t
0.42 3.26 4.66 215
0.48 3.70 5.28 189
0.60 4.59 6.56 152

Tolerances
Length:  +0mm, -15mm
Cover Width:  + 4 mm, -4mm

Spanning Tables
The maximum recommended support spacings are based on testing in accordance with AS 1562 – 1992, Design and installation of sheet roof and wall cladding – Part 1: Metal and AS 4040.1 – 1992 Methods of testing sheet roof and wall cladding, Method 1: Resistance to concentrated loads.

These roof spacings are the maximum recommended for adequate performance of the roof cladding under foot traffic loading. These spacings may be reduced by the Serviceability and Strength Limit States for the particular project under consideration.

Maximum Recommended Support Spacing (mm)
Type of Span Thickness (mm) BMT
0.42 0.48 0.60
Roofs
Single Span
End Span
Internal Span
Unstiffened Eaves Overhang
Stiffened Eaves Overhang
1600
1700
2100
150
500
2000
2550
3000
150
500
2600
2900
3600
200
750
Walls
Single Span
End Span
Internal Span
2600
2400
3000
3000
3000
3200
3000
3200
3500


Capacity & Load Tables
The wind pressure capacities are based on tests conducted at BlueScope's NATA registered testing laboratory.

Testing was conducted in accordance with AS 1562.1 - 1992, Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 - 1992, Resistance to Wind Pressure for non-cyclonic Regions.

The table for wind pressure capacities provides pressure versus span information for Serviceability and Strength Limit State design.

Serviceability Limit State is based on a deflection limit of: (span/120) + (P/30), where P is the maximum fastener pitch.

The pressure capacities for Strength Limit State have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable when the cladding is fixed to a minimum of 1.0 mm material (G550).

To obtain the design capacity of sheeting, a capacity reduction factor should be applied (ø = 0.9).

LYSAGHT KLIP-LOK® 700 Wind Capacities (kPa) - Limit State Format
Base Metal
Thickness (mm)
Type of Span Limit
State
Span (mm)
900 1200 1500 1800 2100
0.42 Single Serviceability 1.47 1.52 1.42 1.21 0.96
Strength 2.55 2.90 2.90 2.65 2.30
End Serviceability 1.37 1.35 1.30 1.22 1.11
Strength 2.70 2.25 2.00 1.85 1.80
Internal Serviceability 1.35 1.38 1.39 1.36 1.30
Strength 2.85 2.70 2.55 2.45 2.30
0.48 Single Serviceability 1.98 1.85 1.62 1.34 1.05
Strength 3.95 3.60 3.25 3.00 2.75
End Serviceability 1.88 1.74 1.60 1.47 1.33
Strength 3.80 3.45 3.20 2.95 2.70
Internal Serviceability 1.77 1.71 1.64 1.57 1.50
Strength 3.60 3.35 3.00 2.70 2.30
0.60 Single Serviceability 3.33 3.01 2.60 2.12 1.66
Strength 7.40 6.90 6.05 5.10 4.05
End Serviceability 3.34 3.10 2.82 2.51 2.19
Strength 5.80 4.75 4.00 3.55 3.35
Internal Serviceability 3.30 3.13 2.95 2.75 2.53
Strength 5.90 4.85 4.00 3.50 3.30


LYSAGHT KLIP-LOK® 700 Wind Capacities (kPa) - Limit State Format
Base Metal
Thickness (mm)
Type of Span Limit
State
Span (mm)
2400 2700 3000 3300 3600
0.42 Single Serviceability 0.74 0.60 0.52  -  -
Strength 2.00 1.70 1.55  -  -
End Serviceability 0.99 0.86 0.73 0.60 0.47
Strength 1.80 1.65 1.45 1.25 1.00
Internal Serviceability 1.21 1.12 1.03 0.93 0.84
Strength 2.15 1.95 1.70 1.45 1.20
0.48 Single Serviceability 0.81 0.66 0.57  -  -
Strength 2.50 2.15 1.80  -  -
End Serviceability 1.20 1.06 0.92 0.77 0.63
Strength 2.50 2.15 1.80 1.40 1.00
Internal Serviceability 1.42 1.34 1.26 1.17 1.09
Strength 1.95 1.65 1.45 1.35 1.25
0.60 Single Serviceability 1.26 0.97 0.75  -  -
Strength 3.20 2.50 2.00  -  -
End Serviceability 1.88 1.60 1.36 1.12 0.91
Strength 3.20 2.85 2.35 1.75 1.10
Internal Serviceability 2.29 2.03 1.76 1.48 1.20
Strength 3.20 2.90 2.45 1.90 1.30

Size Availability

NSW/ACT

VIC

TAS

QLD

NT

SA

WA

By Enquiry* By Enquiry*  By Enquiry* Available  By Enquiry* By Enquiry* By Enquiry*


NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads.


For further information please download Lysaght's Klip-Loc 700 Product Brochure. It is available in a PDF format from below:

Klip-Loc 700 Product Brochure. (585kb)


All products contained herein © BlueScope Lysaght. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd.
All rights reserved.