Selector.com
Selector.com - Part of Architecture Media Product Network Australian Institute of Architects
Selector.com
Home | About Us | Contact Us | Links | Sitemap Advertise your products
  or    or  Guest
Existing user?  Login
New to site?  Register
 
COMPANY INFORMATION
PRODUCT INFORMATION
Residential Roof Cladding
 Photographs
 Colours & TexturesClick to view subproduct listing
 Technical Data
Lysaght Custom Orb®
Lysaght Custom Blue Orb®
Lysaght Trimdek®
Lysaght Spandek®
Lysaght Klip-Lok® 406
Lysaght klip-Lok® 700
 Specify ProductClick to view subproduct listing
 ApplicationsClick to view subproduct listing
 Install, MaintainClick to view subproduct listing
 FeaturesClick to view subproduct listing
 Appraisals, TestsClick to view subproduct listing
Other products by this company
Residential Carports & Verandahs
Residential Flooring
Fencing
Steel Beams
more products...
EDITORIAL
Architects Handbook
The Lysaght Roofing Range – Quality And Style
Lysaght Structural Products
Lysaght Mini Orb®
Lysaght W-dek®
Lysaght Mini Orb®
Lysaght Quikafloor® – Steel For Strength
The Lysaght® Roofing Range
Architectural Product News
A FRESH APPROACH TO FACADE SOLUTIONS
THERE’S SOMETHING UNIQUE BEHIND THE BEST FACADES ...
Similar products by all companies
Metal roofing
 

Home > BlueScope Lysaght > Residential Roof Cladding

  RESIDENTIAL ROOF CLADDING
  Technical Data : Lysaght Custom Orb®

Lysaght Custom Orb®
Schematic



Physical Properties
Mass and Yield
Thickness
(mm) BMT
ZINCALUME® steel
kg/m kg/m2 m2/t
0.42
0.48
3.26
3.70
4.28
4.86
234
206

Tolerances
Length: + 10 mm, - 10 mm
Cover Width: + 4 mm, - 4 mm

Spanning Tables
The maximum recommended support spacings are based on testing in accordance with AS 1562.1 1992, Design and installation of Sheet Roof and Wall Cladding and AS 4040.1 - 1992, Resistance to Concentrated Loads.

The wall spacings are based on pressures for buildings up to 10m high in Region B, Terrain Category 3 conditions (Vs = 38 m/s and Vu = 60 m/s) using Cpe = 0.65, Cpi = 0.2 and Kl = 2.0.

Spacings may be reduced by the Serviceability and Strength Limit States for the particular project under consideration.

Maximum Recommended Support Spacings
Type of Span Thickness (mm) BMT
0.42 0.48
Roofs
Single Span
End Span
Internal Span
Unstiffened Eaves Overhang
Stiffened Eaves Overhang
700
900
1200
200
300
800
1300
1700
250
350
Walls
Single Span
End Span
Internal Span
Overhang
1800
2500
2700
200
1800
2700
2700
250
With foot-traffic loading.
Supports must not be less than 1 mm BMT.

Capacity & Load Tables
The wind pressure capacities are based on  full scale tests carried out at BlueScope's NATA Registered Testing Laboratory using the direct pressure-testing rig.

Testing was conducted in accordance with AS 1562.1 - 1992. Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 - 1992, Resistance to Wind Pressures for non-cyclonic Regions.

The pressure capacities for serviceability are based on a deflection limit of (span/120) + (maximum fastener pitch/30).

The pressure capacities for strength have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable to the cladding being fixed to a minimum of 1.0 mm, G550 steel

LYSAGHT CUSTOM ORB® Wind Capacities (kPa) - Limit State Format
Base Metal
Thickness (mm)
Type of
Span
Fasteners
per sheet
per support
Limit
State
Span (mm)
600 900 1200 1500
0.42 Single 3 Serviceability 1.91 1.46 1.08 0.77
Strength* 12.00  8.60 5.80 4.65 
5 Serviceability 5.39 3.20 2.07 1.19
Strength* 12.00 12.00 10.25 8.20
End 3 Serviceability 1.66 1.40 1.18 1.00
Strength* 9.15 7.55  5.90 4.50 
5 Serviceability 6.08 4.27 2.79 1.59
Strength* 12.00  12.00  9.90  7.55 
Internal 3 Serviceability 1.91 1.67 1.45 1.23
Strength* 13.35  9.25  7.45  6.00
5 Serviceability 7.00 4.92 3.32 2.21
Strength* 12.00 12.00 12.00 10.80
0.48 Single 3 Serviceability 2.12 1.47 1.03 0.77
Strength* 12.00 9.80 6.55 5.30
5 Serviceability 7.48 3.74 1.56 0.73
Strength* 12.00 12.00 9.65 7.75
End 3 Serviceability 1.92 1.66 1.48 1.35
Strength* 11.70 9.05 6.80 4.95 
5 Serviceability 8.00 4.75 2.86 1.97
Strength* 12.00 12.00 12.00 10.60
Internal 3 Serviceability 1.98 1.96 1.84 1.62
Strength* 12.00 10.15 8.50  7.10
5 Serviceability 6.50 5.42 4.34 3.31
Strength* 12.00 12.00 12.00 12.00


LYSAGHT CUSTOM ORB® Wind Capacities (kPa) - Limit State Format
Base Metal
Thickness (mm)
Type of
Span
Fasteners
per sheet
per support
Limit
State
Span (mm)
1800 2100 2400 2700
0.42 Single 3 Serviceability 0.49  -  -  -
Strength* 4.50  -  -  -
5 Serviceability 0.45  -  -  -
Strength* 6.65  -  -  -
End 3 Serviceability 0.83 0.67 0.52 0.38
Strength* 3.40 2.70  2.30 2.00
5 Serviceability 1.02 0.65 0.42 0.30
Strength* 5.75  4.50 3.60 3.05
Internal 3 Serviceability 1.03 0.85 0.69 0.56
Strength* 4.85 3.90 3.20 2.70
5 Serviceability 1.49 1.05 0.78 0.59
Strength* 8.85 7.10 5.65 4.50
0.48 Single 3 Serviceability 0.60  -  -  -
Strength* 5.10  -  -  -
5 Serviceability 0.57  -  -  -
Strength* 7.25   -  -  -
End 3 Serviceability 1.19 1.01 0.81 0.60
Strength* 4.10 3.45 3.00 2.65
5 Serviceability 1.39 0.97 0.66 0.44
Strength* 8.00 6.20 5.00 4.25
Internal 3 Serviceability 1.36 1.07 0.82 0.62
Strength* 5.70 4.55 3.60 2.90
5 Serviceability 2.37 1.57 0.95 0.54
Strength* 11.00 8.65 6.75 5.25
* A capacity reduction factor of = 0.9 has been applied to strength capacities.

NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads.



For more comprehensive information, please download the Lysaght's Custom Orb Product Brochure from below. It is available in a PDF file format from www.bhpsteel.com.

Custom Orb Product Brochure (41kb)