Home >
BlueScope Lysaght >
Residential Roof Cladding
RESIDENTIAL ROOF CLADDING
Technical Data :
Lysaght Custom Orb® |
|
|
Lysaght Custom Orb®
|
Schematic
/2366001A001.GIF)
Physical Properties
| Mass and Yield |
Thickness
(mm) BMT |
ZINCALUME® steel |
| kg/m |
kg/m2 |
m2/t |
0.42
0.48 |
3.26
3.70 |
4.28
4.86 |
234
206 |
Tolerances
Length: + 10 mm, - 10 mm
Cover Width: + 4 mm, - 4 mm
Spanning Tables
The maximum recommended support spacings are based on testing in accordance with AS 1562.1 1992, Design and installation of Sheet Roof and Wall Cladding and AS 4040.1 - 1992, Resistance to Concentrated Loads.
The wall spacings are based on pressures for buildings up to 10m high in Region B, Terrain Category 3 conditions (Vs = 38 m/s and Vu = 60 m/s) using Cpe = 0.65, Cpi = 0.2 and Kl = 2.0.
Spacings may be reduced by the Serviceability and Strength Limit States for the particular project under consideration.
| Maximum Recommended Support Spacings |
| Type of Span |
Thickness (mm) BMT |
| 0.42 |
0.48 |
| Roofs |
Single Span
End Span
Internal Span
Unstiffened Eaves Overhang
Stiffened Eaves Overhang |
700
900
1200
200
300
|
800
1300
1700
250
350 |
| Walls |
Single Span
End Span
Internal Span
Overhang |
1800
2500
2700
200 |
1800
2700
2700
250 |
With foot-traffic loading.
Supports must not be less than 1 mm BMT. |
Capacity & Load Tables
The wind pressure capacities are based on full scale tests carried out at BlueScope's NATA Registered Testing Laboratory using the direct pressure-testing rig.
Testing was conducted in accordance with AS 1562.1 - 1992. Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 - 1992, Resistance to Wind Pressures for non-cyclonic Regions.
The pressure capacities for serviceability are based on a deflection limit of (span/120) + (maximum fastener pitch/30).
The pressure capacities for strength have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable to the cladding being fixed to a minimum of 1.0 mm, G550 steel
| LYSAGHT CUSTOM ORB® Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness (mm) |
Type of
Span |
Fasteners
per sheet
per support |
Limit
State |
Span (mm) |
| 600 |
900 |
1200 |
1500 |
| 0.42 |
Single |
3 |
Serviceability |
1.91 |
1.46 |
1.08 |
0.77 |
| Strength* |
12.00 |
8.60 |
5.80 |
4.65 |
| 5 |
Serviceability |
5.39 |
3.20 |
2.07 |
1.19 |
| Strength* |
12.00 |
12.00 |
10.25 |
8.20 |
| End |
3 |
Serviceability |
1.66 |
1.40 |
1.18 |
1.00 |
| Strength* |
9.15 |
7.55 |
5.90 |
4.50 |
| 5 |
Serviceability |
6.08 |
4.27 |
2.79 |
1.59 |
| Strength* |
12.00 |
12.00 |
9.90 |
7.55 |
| Internal |
3 |
Serviceability |
1.91 |
1.67 |
1.45 |
1.23 |
| Strength* |
13.35 |
9.25 |
7.45 |
6.00 |
| 5 |
Serviceability |
7.00 |
4.92 |
3.32 |
2.21 |
| Strength* |
12.00 |
12.00 |
12.00 |
10.80 |
| 0.48 |
Single |
3 |
Serviceability |
2.12 |
1.47 |
1.03 |
0.77 |
| Strength* |
12.00 |
9.80 |
6.55 |
5.30 |
| 5 |
Serviceability |
7.48 |
3.74 |
1.56 |
0.73 |
| Strength* |
12.00 |
12.00 |
9.65 |
7.75 |
| End |
3 |
Serviceability |
1.92 |
1.66 |
1.48 |
1.35 |
| Strength* |
11.70 |
9.05 |
6.80 |
4.95 |
| 5 |
Serviceability |
8.00 |
4.75 |
2.86 |
1.97 |
| Strength* |
12.00 |
12.00 |
12.00 |
10.60 |
| Internal |
3 |
Serviceability |
1.98 |
1.96 |
1.84 |
1.62 |
| Strength* |
12.00 |
10.15 |
8.50 |
7.10 |
| 5 |
Serviceability |
6.50 |
5.42 |
4.34 |
3.31 |
| Strength* |
12.00 |
12.00 |
12.00 |
12.00 |
| LYSAGHT CUSTOM ORB® Wind Capacities (kPa) - Limit State Format |
Base Metal
Thickness (mm) |
Type of
Span |
Fasteners
per sheet
per support |
Limit
State |
Span (mm) |
| 1800 |
2100 |
2400 |
2700 |
| 0.42 |
Single |
3 |
Serviceability |
0.49 |
- |
- |
- |
| Strength* |
4.50 |
- |
- |
- |
| 5 |
Serviceability |
0.45 |
- |
- |
- |
| Strength* |
6.65 |
- |
- |
- |
| End |
3 |
Serviceability |
0.83 |
0.67 |
0.52 |
0.38 |
| Strength* |
3.40 |
2.70 |
2.30 |
2.00 |
| 5 |
Serviceability |
1.02 |
0.65 |
0.42 |
0.30 |
| Strength* |
5.75 |
4.50 |
3.60 |
3.05 |
| Internal |
3 |
Serviceability |
1.03 |
0.85 |
0.69 |
0.56 |
| Strength* |
4.85 |
3.90 |
3.20 |
2.70 |
| 5 |
Serviceability |
1.49 |
1.05 |
0.78 |
0.59 |
| Strength* |
8.85 |
7.10 |
5.65 |
4.50 |
| 0.48 |
Single |
3 |
Serviceability |
0.60 |
- |
- |
- |
| Strength* |
5.10 |
- |
- |
- |
| 5 |
Serviceability |
0.57 |
- |
- |
- |
| Strength* |
7.25 |
- |
- |
- |
| End |
3 |
Serviceability |
1.19 |
1.01 |
0.81 |
0.60 |
| Strength* |
4.10 |
3.45 |
3.00 |
2.65 |
| 5 |
Serviceability |
1.39 |
0.97 |
0.66 |
0.44 |
| Strength* |
8.00 |
6.20 |
5.00 |
4.25 |
| Internal |
3 |
Serviceability |
1.36 |
1.07 |
0.82 |
0.62 |
| Strength* |
5.70 |
4.55 |
3.60 |
2.90 |
| 5 |
Serviceability |
2.37 |
1.57 |
0.95 |
0.54 |
| Strength* |
11.00 |
8.65 |
6.75 |
5.25 |
* A capacity reduction factor of = 0.9 has been applied to strength capacities.
NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads.
For more comprehensive information, please download the Lysaght's Custom Orb Product Brochure from below. It is available in a PDF file format from www.bhpsteel.com.
Custom Orb Product Brochure (41kb)
|
|
|
All products contained herein © BlueScope Lysaght. Page layout © 1996-2008 Architecture Media (Selector) Pty Ltd. All rights reserved.
|
|
|