Selector.com
Selector.com - Part of Architecture Media Product Network Australian Institute of Architects
Selector.com
Home | About Us | Contact Us | Links | Sitemap Advertise your products
  or    or  Guest
Existing user?  Login
New to site?  Register
 
COMPANY INFORMATION
PRODUCT INFORMATION
Commercial Wall Cladding
 Photographs
 Colours & TexturesClick to view subproduct listing
 Technical Data
Lysaght Wallclad®
Lysaght Trimwall®
Lysaght Panelrib®
Lysaght Multiclad®
Lysaght Mini Orb®
Lysaght Multiline™
 Specify ProductClick to view subproduct listing
 ApplicationsClick to view subproduct listing
 Install, MaintainClick to view subproduct listing
 FeaturesClick to view subproduct listing
 Appraisals, TestsClick to view subproduct listing
Other products by this company
Residential Carports & Verandahs
Residential Flooring
Fencing
Steel Beams
more products...
EDITORIAL
Architects Handbook
The Lysaght Roofing Range – Quality And Style
Lysaght Structural Products
Lysaght Mini Orb®
Lysaght W-dek®
Lysaght Mini Orb®
Lysaght Quikafloor® – Steel For Strength
The Lysaght® Roofing Range
Architectural Product News
A FRESH APPROACH TO FACADE SOLUTIONS
THERE’S SOMETHING UNIQUE BEHIND THE BEST FACADES ...
Similar products by all companies
Metal wall cladding
 

Home > BlueScope Lysaght > Commercial Wall Cladding

  COMMERCIAL WALL CLADDING
  Technical Data : Lysaght Wallclad®

Lysaght Wallclad®
Schematic



Physical Properties
Mass and Yield BMT (mm) kg/m kg/m2 m2/t
ZINCALUME® steel 0.35 2.74 3.60 278

Tolerance
Cover: 762mm +/-4mm
Length Tolerance:  +0, -10mm

Spanning Tables
The wall spacings indicated are the maximum recommended for buildings up to 10 m high in Region B Terrain Category 3 conditions (Vs = 38 m/s and Vu = 60 m/s), using Cpe = 0.65, Cpi = 0.2 and Kl = 2.0.

These spacings may be reduced by the Serviceability and Strength wind conditions for the particular project under consideration.

Maximum Recommended Support Spacings (mm)
Type of Span Thickness (mm)
Walls 0.35
Single Span
End Span
Internal Span
Overhang
2100
2400
2400
150

Capacity & Load Tables
The wind pressure capacities are based on tests conducted at BlueScope's NATA registered testing laboratory.

Testing was conducted in accordance with AS 1562.1 - 1992, Design and Installation of Sheet Roof and Wall Cladding, and AS 4040.2 - 1992, Resistance to Wind Pressure for Non-cyclonic Regions.

Serviceability Limit State is based on a deflection limit of: (span/120) + (P/30), where P is the maximum fastener pitch.

Strength Limit State capacities have been determined by testing the cladding to failure (ultimate capacity). These pressures are applicable when the cladding is fixed to a minimum of 1.0 mm material (G550).

Strength pressures are reduced when fixed to material <1.0 mm.

To obtain the design capacity of sheeting, a capacity reduction factor should be applied (ø = 0.9).

LYSAGHT WALL-CLAD® - Wind Capacities (kPa) Limit State Format
Base
Metal
Thickness
Type
of
Span
Fasteners
per sheet
per support
Limit
State
Span (mm)
600 900 1200 1500
0.35 Single 3 Serviceability 1.32 1.21 1.07 0.87
Strength 12.0 9.35 7.10 5.75
5 Serviceability 5.00 3.16 1.72 1.06
Strength 12.0 12.0 11.8 9.90
End 3 Serviceability 1.32 1.29 1.23 1.12
Strength 10.00 7.35 5.05 3.30
5 Serviceability 6.55 4.64 2.93 1.64
Strength 12.00 11.15 8.15 5.80
Internal 3 Serviceability 1.33 1.32 1.31 1.28
Strength 10.70 8.10 6.00 4.70
5 Serviceability 6.38 4.83 3.48 2.46
Strength 12.00 12.00 9.50 7.60

LYSAGHT WALL-CLAD® - Wind Capacities (kPa) Limit State Format
Base
Metal
Thickness
Type
of
Span
Fasteners
per sheet
per support
Limit
State
Span (mm)
1800 2100 2400
0.35 Single 3 Serviceability 0.65 0.41 0.17
Strength 4.65 3.80 3.00
5 Serviceability 0.63 0.36 0.17
Strength 8.15 6.45 4.80
End 3 Serviceability 0.93 0.68 0.41
Strength 2.30 1.90 1.80
5 Serviceability 0.90 0.58 0.46
Strength 4.30 3.50 3.00
Internal 3 Serviceability 1.16 1.00 0.82
Strength 3.65 2.80 2.00
5 Serviceability 1.72 1.15 0.64
Strength 6.00 4.50 3.10

NOTE:
This information is suitable for use only in non-cyclonic areas, that is where a tropical cyclone is unlikely to occur, in accordance with AS 1170.2 - 1989, SAA Loading Code, Part 2, Wind Loads.


For further information please download Lysaght's Wallclad Product Information Brochure. It is available from below in a PDF format.